The photovoltaic (PV) pumping system is a widely used application in Mauritania to ensure the water supply in rural area for populations needs. The system is composed of a PV generator, a DC/DC converter, a DC/AC inverter, a BLDC motor and a centrifugal pump. Study in this article we study with simulation in Matlab/ Simulink environment the performances of the PV pumping system taking into account the climate parameters (solar irradiance, and ambient temperature), and the effect of the total manometric head (HMT) on the pumped flow rate. In addition it also counted the electrical energy and flow rate of the each climatic parameter. Two mathematical motor –pump models for PV application, were proposed in this article to contribute in the studies of PV pumping sizing. These models link directly the operating current to the voltage and electrical power to the flow rate of the pump versus total head.
Published in | American Journal of Energy Engineering (Volume 7, Issue 1) |
DOI | 10.11648/j.ajee.20190701.11 |
Page(s) | 1-7 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2019. Published by Science Publishing Group |
Generator Photovoltaic, System, Power, Converter, Motor-pump, Flow Rate, Total Manometric Head (HMT)
[1] | K. Meah, S. Fletcher, S. Ula, Solar photovoltaic water pumping for remote locations, Renew. Sustain. Energy Rev. 2008. |
[2] | J. H. Eckstein, ''Detailed Modelling of Photovoltaic System Components’, MS Thesis, Mechanical Engineering'', University of Wisconsin, Madison, 1990. |
[3] | A. A. Ghoneim, ''Design optimization of photovoltaic powered water pumping systems'', Energy Convers. Manag. 2006. |
[4] | B. G. Belgacem, Performance of submersible PV water pumping systems in Tunisia, Energy Sustain. Dev. 2012. |
[5] | A. Hamidat and B. Benyoucef, ''Mathematic Models of Photovoltaic Motor-Pump Systems'', Renewable Energy, Mai 2008. |
[6] | B. Yesilata and Z. A. Firatoglu, Effect of solar radiation correlations on system sizing: PV pumping case, Renew. Energy. 2018. |
[7] | Chueco-Fernandez Francisco J, Bayod-Rujula Angel A. ‘'Power supply for pumping systems in northern Chile: photovoltaic as alternative to grid extension and diesel engines'' Renew. Energy 2010. |
[8] | A. Al-Badi, H. Yousef, T. ''Sizing and modelling of photovoltaic water pumping system'', University, Muscat, Sultanate of Oman, INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2017. |
[9] | M. El Mamy. M. Mahmoud, Ahmed. Yahfdhou, O. H. Lemrabott, Chighali Ehssein, A K Mahmoud, I. Youm ''Photovoltaic Pumping System for Application to Sites in Mauritania'' International Journal of Innovative Technology and Exploring Engineering (IJITEE) ISSN: 2278-3075, Volume-6 Issue-5, October 2016. |
[10] | Abdellahi Ba et al, “Performance Optimisation of the PV pumping system”, Procedia Manufacturing, 2018. |
[11] | F. B. Pelap, P. D. Dongo, A. D. Kapim, ''Optimization of the characteristics of the PV cells using nonlinear electronic components'', Sustain. Energy Technol. Assess, 2016. |
[12] | A. Hadj Arab, M. Benghanem and F. ''Motor-Pump System Modelization'', Renewable Energy, Juin 2006. |
[13] | Kou, Q, Klein, S. A, Beckam, Q, A. ''A methode for estimating the long-term performance of direct-coupled PV pumping systems'' Sol. Energy 64, 33-40. 1998. |
[14] | Hamidat et al, ''Mathematic models of photovoltaic motor-pump systems'', Renewable Energy 33, 2008. |
[15] | A. Mohammedi, N. Mezzai, D. Rekioua, T. Rekioua, Impact of shadow on the performances of a domestic photovoltaic pumping system incorporating an MPPT control: A case study in Bejaia, North Algeria, Energy Convers. Manag. 84 (2014) 20–29. |
[16] | Mahmoud, M. E. M., Soukeyna, M., Yahfdhou, A., Mahmoud, A. K. and Youm, I. 2019. Sizing Method of a Storage System for Determining the Performance of a Photovoltaic Pumping System over the Sun. Smart Grid and Renewable Energy, 10: 17-28. |
[17] | Hamidat A. Simulation of the performance and cost calculations of the surface pump. Renew Energy 1999. |
APA Style
Mohamed El Mamy Mohamed Mahmoud, Jeyid Yacoub El Moubarrack, Chighali Ehssein, Ahmed Mohamed Yahya, Abdel Kader Mahmoud, et al. (2019). Performance Optimization and Modelization of a Photovoltaic Pumping System. American Journal of Energy Engineering, 7(1), 1-7. https://doi.org/10.11648/j.ajee.20190701.11
ACS Style
Mohamed El Mamy Mohamed Mahmoud; Jeyid Yacoub El Moubarrack; Chighali Ehssein; Ahmed Mohamed Yahya; Abdel Kader Mahmoud, et al. Performance Optimization and Modelization of a Photovoltaic Pumping System. Am. J. Energy Eng. 2019, 7(1), 1-7. doi: 10.11648/j.ajee.20190701.11
AMA Style
Mohamed El Mamy Mohamed Mahmoud, Jeyid Yacoub El Moubarrack, Chighali Ehssein, Ahmed Mohamed Yahya, Abdel Kader Mahmoud, et al. Performance Optimization and Modelization of a Photovoltaic Pumping System. Am J Energy Eng. 2019;7(1):1-7. doi: 10.11648/j.ajee.20190701.11
@article{10.11648/j.ajee.20190701.11, author = {Mohamed El Mamy Mohamed Mahmoud and Jeyid Yacoub El Moubarrack and Chighali Ehssein and Ahmed Mohamed Yahya and Abdel Kader Mahmoud and Issakha Youm}, title = {Performance Optimization and Modelization of a Photovoltaic Pumping System}, journal = {American Journal of Energy Engineering}, volume = {7}, number = {1}, pages = {1-7}, doi = {10.11648/j.ajee.20190701.11}, url = {https://doi.org/10.11648/j.ajee.20190701.11}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajee.20190701.11}, abstract = {The photovoltaic (PV) pumping system is a widely used application in Mauritania to ensure the water supply in rural area for populations needs. The system is composed of a PV generator, a DC/DC converter, a DC/AC inverter, a BLDC motor and a centrifugal pump. Study in this article we study with simulation in Matlab/ Simulink environment the performances of the PV pumping system taking into account the climate parameters (solar irradiance, and ambient temperature), and the effect of the total manometric head (HMT) on the pumped flow rate. In addition it also counted the electrical energy and flow rate of the each climatic parameter. Two mathematical motor –pump models for PV application, were proposed in this article to contribute in the studies of PV pumping sizing. These models link directly the operating current to the voltage and electrical power to the flow rate of the pump versus total head.}, year = {2019} }
TY - JOUR T1 - Performance Optimization and Modelization of a Photovoltaic Pumping System AU - Mohamed El Mamy Mohamed Mahmoud AU - Jeyid Yacoub El Moubarrack AU - Chighali Ehssein AU - Ahmed Mohamed Yahya AU - Abdel Kader Mahmoud AU - Issakha Youm Y1 - 2019/05/23 PY - 2019 N1 - https://doi.org/10.11648/j.ajee.20190701.11 DO - 10.11648/j.ajee.20190701.11 T2 - American Journal of Energy Engineering JF - American Journal of Energy Engineering JO - American Journal of Energy Engineering SP - 1 EP - 7 PB - Science Publishing Group SN - 2329-163X UR - https://doi.org/10.11648/j.ajee.20190701.11 AB - The photovoltaic (PV) pumping system is a widely used application in Mauritania to ensure the water supply in rural area for populations needs. The system is composed of a PV generator, a DC/DC converter, a DC/AC inverter, a BLDC motor and a centrifugal pump. Study in this article we study with simulation in Matlab/ Simulink environment the performances of the PV pumping system taking into account the climate parameters (solar irradiance, and ambient temperature), and the effect of the total manometric head (HMT) on the pumped flow rate. In addition it also counted the electrical energy and flow rate of the each climatic parameter. Two mathematical motor –pump models for PV application, were proposed in this article to contribute in the studies of PV pumping sizing. These models link directly the operating current to the voltage and electrical power to the flow rate of the pump versus total head. VL - 7 IS - 1 ER -